BTU Calculator
Room-by-room heating and cooling load in BTU/h from area, climate zone and envelope.
BTU/h · Manual J
Load calculations, duct sizing, static pressure and running cost — the numbers an HVAC job actually turns on, as tools you can print.

Room-by-room heating and cooling load in BTU/h from area, climate zone and envelope.
BTU/h · Manual J
Input BTU/h and output capacity from load, climate zone and AFUE.
BTU/h · AFUE
Annual cooling cost and payback when you move from one SEER2 rating to another.
SEER2 · $/yr
Installed cost band by system type, tonnage and region, with the line items.
$ · installed
Tonnage for a whole house, with the oversizing check most rules of thumb skip.
tons · sq ft
Round and rectangular duct sizes from CFM and friction rate, with equivalent diameter.
CFM · in. w.c./100 ft
01
Room by room, with your actual glass, insulation and design temperatures. Not square feet times a number someone remembered.
Manual J worksheet02
Static pressure first, then the friction rate, then the sizes. A system that cannot move the air will not deliver the capacity you bought.
Static pressure calculator03
AFUE, SEER2 and HSPF2 are three different scales. Convert them all to dollars per delivered MMBtu and the comparison becomes arithmetic.
Fuel cost calculatorColour means temperature here, not decoration. Warm is the heating side, cool is the cooling side, and the two neutral sections are the ones that measure both.

5 tools, 4 guides
Manual J load, BTU/h, tonnage, duct sizing and static pressure — the numbers that decide what equipment goes in.

3 tools, 5 guides
Furnaces, heat pumps and the efficiency ratings that price them — AFUE, HSPF2 and the cold-climate question.

3 tools, 5 guides
Air conditioners, mini splits, refrigerant and SEER2 — the cool side of the manifold.

4 tools, 5 guides
Replacement cost, maintenance, filters and the credits that move the price — what the job costs and what keeps it running.
Why square-foot rules of thumb oversize, and what to measure instead.
9 min read
Capacity at 5°F, balance points, and when a dual-fuel setup wins.
11 min read
What changed in 2023, how SEER converts to SEER2, and the regional minimums.
9 min read
What a full system costs installed in 2026, and which line items move it.
11 min read
Running but not cold, frozen coil, compressor silent — a decision list.
12 min read
25C, the heat-pump caps, and what the 2025 law changed about the deadline.
9 min read
40 pages, 15 calculators, and every regulatory figure on the site read from its primary source and stamped with the date. No accounts, no sign-up, nothing stored.